Chinese Journal of Blood Transfusion ; (12): 13-16, 2022.
Article in Chinese | WPRIM | ID: wpr-1004032

ABSTRACT

【Objective】 To explore ways to recruit blood donors effectively, so as to ensure blood supply for hospitals in Shenzhen with good compliance with the requirements concerning COVID-19 prevention and control. 【Methods】 From January 31 to March 31, 2020, a recruiting vanguard lead by Party members aimed at "COVID-19 control, blood supply security" was established. Otherwise, the traditional recruiting (via telephone/SMS) and on-site(on the streets) recruiting were also enhanced. The effects of the above three recruitment methods during this period, relative to the same period in 2019, were counted and analyzed. 【Results】 A total of 19 752 blood donors were recruited, and more were recruited by on-site (15 643, 79.19%) than by telephone and SMS(4 109, 20.81%), as on-site recruitment was more persuasive than the traditional one. The success rates of telephone recruitment and SMS recruitment were 11.66% (2 034 / 17 448) and 3.92% (2 075/52 915), respectively, and both were significantly higher than that in the same period in 2019(7.55% and 2.36%) (P0.05). 【Conclusion】 In times of emergency, efficient recruiting method could be achieved by grouping a vanguard, conducting scientific measures, and carrying out effect evaluation. Besides, preference could be given to donors with local registered residence, middle-age (30~50 years old) and better educated background.

2.
Chinese Journal of Blood Transfusion ; (12): 128-131, 2021.
Article in Chinese | WPRIM | ID: wpr-1004614

ABSTRACT

【Objective】 To verify the key performance parameters of Roche Cobas S201 multiplex NAT for blood donors, so as to provide data for the conformation of multiplex NAT performance and establish a scientific and feasible verification scheme. 【Methods】 Comprehensive performance verification on four key parameters of ROCHE COBAS S201 multiplex NAT system, including the 95% detection limit, compliance rate, anti-interference ability and operator comparison were conducted. The data were compared with the specifications provided by the manufacturer to evaluate the performance of laboratory testing system and ensure the quality of blood testing. 【Results】 2 sets of COBAS S201 multiplex NAT system in our laboratory were used to perform 5 times of the 95% detection limit value declared by the manufacturer for individual tests. The experimental results showed that the target NAT can be detected 100% and the lower limit of determination was verified. Single-virus NAT was performed to detect 5 different HBV DNA concentrations (25 ~400 IU/mL), 5 different HCV RNA concentrations (25 ~400 IU/mL), 5 different HIV RNA Concentration (100~1 000 IU/mL), and 5 negative tubes. The experimental results showed that all detected values of 20 tubes were 100% consistent with the true value, and the performance parameter "coincidence rate" was verified. Samples containing lipoemia, hemolysis, with ALT>50 mL/L and syphilis-positive endogenous interfering substances with 3 times of the 95% detection limit value were tested for 3 times, and results showed both response rate (3/3) and yielding rate reached 100%. In the control group (with none or in the normal range of interfering substances), reactivity was detected in samples with extremely low concentration of 3 times of the 95% detection limit, showing no significant difference (P>0.05). Above results fully showed that the existence of interference substances (lipidemia, hemolysis, ALT ≥ 50 and syphilis positive) in the blood of donors had no significant effect on the yielding of HBV/HCV/HIV virus target nucleic acids. Different operators performed the sample loading tests with same instrument, reagent and specimen showed 100% consistency in the results. It could be preliminarily assessed that there was no difference in the operations between the operators in this verification. 【Conclusion】 The verification scheme of the multiplex NAT system for methodology performance index (95% detection limit, coincidence rate, anti-interference ability, and operator comparison) established in this study, showed simple, flexible, scientific and feasible characteristics and could provide reference and data support for domestic blood transfusion services in acid detection.

3.
International Journal of Laboratory Medicine ; (12): 157-159,162, 2017.
Article in Chinese | WPRIM | ID: wpr-606126

ABSTRACT

Objective To evaluated the HCV genotyping results which obtained by genotype diagnostic kit in Shenzhen area. Methods 158 samples which ELISA test of anti-HCV were positive were collected from voluntary blood donors from 2014 to 2015,and were tested by PCR fluorescence probe method for viral load.The samples which viral load were greater than 1.0 ×103 IU/mL were then tested by HCV RNA genotype diagnostic kit.To analysis the proportion of different genotypes and the correla-tion between genotypes with vrial load.Results 54 HCV RNA reactive sample were quantity by PCR fluorescence probe method from 158 anti-HCV positive samples.The genotyping data for 45 cases which vrial load greater than 1.0×103 IU/mL were obtained by HCV RNA genotype diagnostic kit.The frequencies HCV genotype 1b,2,3 and 6 were 57.78%(26/45),6.67%(3/45),8.89%(4/45)and 26.67%(12/45),respectively.One-way ANOVA analysis showed that significant difference in viral loads was found be-tween different HCV genotype 1b and 2(F =2.861,P <0.05),and there was a significant difference in viral loads and anti-HCV S/CO by sex(P <0.05).Fisher′s exact test showed the significance difference between age and genotypes(P <0.05 ).Conclusion HCV 1b and 6 were the most predominant genotypes due to the higher viral load than the other subtypes among volunteer blood do-nors in Shenzhen,while the proportion of HCV 2,3 declined.